  • Kenny, P.J.; Chato, J.C.; Dobson, M.K.; Wattelet, J.P.; Gaibel, J.A.; Ponchner, M.; Shimon, R.L.; Villaneuva, T.C.; Rhines, N.L.; Sweeney, K.A.; Allen, D.G.; Hershberger, T.T. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1994-07)
    This experimental study examined the local heat transfer coefficients and frictional pressure gradients of a ternary zeotropic refrigerant mixture, R-32/R-125/R-134a (23%/25%/52%) condensing in a smooth, horizontal tube. ...

    application/pdf

    application/pdfPDF (2Mb)
  • Wattelet, J.P. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1990-08)
    Chlorofluorocarbons are the primary refrigerants used in vapor-compression air conditioning and refrigeration systems. Environmental concerns, such as the ozone depletion effect of chlorofluorocarbons, have led to an ...

    application/pdf

    application/pdfPDF (7Mb)
  • Wattelet, J.P.; Chato, J.C.; Souza, A.L.; Christoffersen, B.R. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1993-05)
    Experimental heat transfer coefficients for R-134a, MP-39, and R-12 are reported herein. Tests were conducted using a single-tube evaporator test facility. The test section used was a 2.43 m (8-foot) long, 7.04 mm ...

    application/pdf

    application/pdfPDF (2Mb)
  • Wattelet, J.P. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1994-05)
    An experimental study of flow boiling heat transfer of refrigerants in a horizontal-tube evaporator was conducted. A single-tube evaporation test facility was designed and developed to measure the evaporation characteristics ...

    application/pdf

    application/pdfPDF (14Mb)
  • Wattelet, J.P.; Chato, J.C.; Souza, A.L.; Christoffersen, B.R. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1993-06)

    application/pdf

    application/pdfPDF (2Mb)
  • Dobson, M.K.; Wattelet, J.P.; Chato, J.C. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1993-06)

    application/pdf

    application/pdfPDF (1Mb)
  • Souza, A.L.; Chato, J.C.; Jabardo, J.M.S.; Wattelet, J.P.; Panek, J.S.; Christoffersen, B.; Rhines, N. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1992-10)
    A single tube evaporator test facility capable of measuring pressure drop and heat transfer coefficients inside horizontal tubes has been designed and developed at the Air Conditioning and Refrigeration Center at the ...

    application/pdf

    application/pdfPDF (1Mb)
  • Smith, M.K.; Wattelet, J.P.; Newell, T.A. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1993-01)
    An average R12 refrigerant correlation has been developed for the mass flux range of 25-100 kg/m2-s and the heat flux range of 2-10 kW/m2. Refrigerant mixtures of 80% R22/lO% R141b and 65% R22/35% R123 have also been ...

    application/pdf

    application/pdfPDF (1Mb)