Title:Destructive Testing of IDOT Bridge Structure Number 020-3087
Author(s):Golecki, Thomas F.; Spencer, B.F.
Subject(s):Load Tests
Prestressed Concrete Bridges
Structural Deterioration and Defects
Laboratory Tests
Abstract:The partial collapse of Illinois Department of Transportation structure 020-3087 on October 1, 2019, provided IDOT with the opportunity to evaluate the in situ strength of a precast, prestressed concrete deck beam bridge after 50 years in service. An undamaged beam was transported to the Newmark Structural Engineering Laboratory and tested in three-point bending to failure on February 25, 2020. The beam supported a peak load of 33.14 kips before failure, an ultimate moment of 227.5 kip-ft. Upon failure, the concrete around the prestressing strands was removed to expose the strands. All strands were present; however, the strands were in a different configuration than shown on design drawings. None of the strands showed visible corrosion.
Issue Date:2020-08
Publisher:Illinois Center for Transportation/Illinois Department of Transportation
Citation Info:Golecki, Thomas F., and B.F. Spencer, Jr. 2020. Destructive Testing of IDOT Bridge Structure Number 020-3087. A report of the findings of ICT-R27-SP42. Illinois Center for Transportation Series No. 20-014. Research Report No. FHWA-ICT-20-008. Illinois Center for Transportation, Rantoul IL. https://doi.org/10.36501/0197-9191/20-014
Series/Report:FHWA-ICT-20-008
Genre:Technical Report
Type:Text
Language:English
URI:http://hdl.handle.net/2142/107800
ISSN:0197-9191
DOI:https://doi.org/10.36501/0197-9191/20-014
Sponsor:IDOT-R27-SP42
Rights Information:No restrictions. This document is available through the National Technical Information Service, Springfield, VA 22161.
Date Available in IDEALS:2020-08-03


This item appears in the following Collection(s)

Item Statistics