Files in this item

FilesDescriptionFormat

application/pdf

application/pdf9215866.pdf (6MB)Restricted to U of Illinois
(no description provided)PDF

Description

Title:Sensitivity and noise analysis of solenoidal coils for nuclear magnetic resonance microscopy
Author(s):Peck, Timothy L.
Doctoral Committee Chair(s):Magin, Richard
Department / Program:Electrical and Computer Engineering
Discipline:Electrical Engineering
Degree Granting Institution:University of Illinois at Urbana-Champaign
Degree:Ph.D.
Genre:Dissertation
Subject(s):Engineering, Electronics and Electrical
Abstract:Conventional NMR studies involve sample volumes $(\upsilon\sb{s})$ of several cubic millimeters and greater. Much recent interest is directed at the development of microscopic NMR systems for the analysis of smaller samples and the visualization of microscopic biological structures. The objective of the research summarized in this thesis is to extend the analysis of RF coils used for NMR to microscopic domains. Microscopic nuclear magnetic resonance suffers from an inherently low SNR, due to the small number of nuclei available to contribute to the signal. Decreasing the size of the RF receive coil provides better coupling between the sample being examined and the coil, i.e., it increases the sensitivity of the coil. We define the sensitivity of a coil as the magnitude of the RF magnetic field that is produced in the coil when a unit current is passed through the windings of the coil.
However, the sensitivity of the coil to detect signals is not the only consideration when determining the SNR, as the noise must also be considered. Noise originates primarily from the resistance of the coil. Electrical circuit models used to characterize large coils (diameters $\geq$ 1 mm) cannot be used for smaller coils, in which the wire diameter approaches one skin depth at the frequency of operation. Therefore, we extend the electrical circuit models which represent the coil to microscopic domains to characterize accurately the SNR performance of RF coils for submillimeter NMR. It is clear from our results that the loss in microcoils can be characterized accurately and that an accurate calculation of the SNR using microcoils can be achieved. Furthermore, the results demonstrate that an enhanced SNR can be achieved in NMR with microcoils as small as 38 $\mu$m, and support the continued reduction of coil size for further enhancement in the SNR.
Issue Date:1992
Type:Text
Language:English
URI:http://hdl.handle.net/2142/21647
Rights Information:Copyright 1992 Peck, Timothy L.
Date Available in IDEALS:2011-05-07
Identifier in Online Catalog:AAI9215866
OCLC Identifier:(UMI)AAI9215866


This item appears in the following Collection(s)

Item Statistics