IDEALS Home University of Illinois at Urbana-Champaign logo The Alma Mater The Main Quad

Interferometric Synthetic Aperture Microscopy (ISAM) Reconstruction and Characterization in a High Numerical Aperture System

Show full item record

Bookmark or cite this item: http://hdl.handle.net/2142/26061

Files in this item

File Description Format
PDF Dabarsyah_Budiman.pdf (958KB) (no description provided) PDF
Title: Interferometric Synthetic Aperture Microscopy (ISAM) Reconstruction and Characterization in a High Numerical Aperture System
Author(s): Dabarsyah, Budiman
Advisor(s): Boppart, Stephen A.
Department / Program: Electrical & Computer Eng
Discipline: Electrical & Computer Engr
Degree Granting Institution: University of Illinois at Urbana-Champaign
Degree: M.S.
Genre: Thesis
Subject(s): High Numerical Aperture Optical System Interferometric Synthetic Aperture Microscopy (ISAM) Optical Coherence Microscopyy Optical Coherence Tomography.
Abstract: Optical coherence microscopy (OCM) is an imaging modality that is capable of visualizing structural features of biological samples at high resolution based on their scattering properties. Interferometric synthetic aperture microscopy (ISAM) is a newer technique that can overcome the typical dependence between lateral resolution and depth-of-focus of an optical coherence tomography (OCT) imaging system by offering spatially invariant resolution within the whole 3D data set, including regions that are outside of the focal region. Both OCM and ISAM have many potential research and clinical applications. By combining OCM and ISAM, it is possible to visualize an entire 3D volumetric data set with the high resolution normally available only at the focus. Therefore, this combination will yield more detailed information from the observed sample than OCM alone. This combination will also improve the feasibility of the ISAM technique for wider research and clinical applications. This thesis presents the experimental validation and characterization of ISAM applied to high numerical aperture OCM optical imaging. The validation includes the image reconstruction of a tissue phantom containing nano-particles both for OCT and ISAM, and system characterization includes quantitative assessment of the confocal parameter, point spread function, and phase stability measurements. Several potential applications also are examined as a part of this thesis.
Issue Date: 2011-08-25
URI: http://hdl.handle.net/2142/26061
Rights Information: Copyright 2011 Budiman Dabarsyah
Date Available in IDEALS: 2011-08-25
Date Deposited: 2011-08
 