IDEALS Home University of Illinois at Urbana-Champaign logo The Alma Mater The Main Quad

Measurement of instantaneous Eulerian acceleration fields by particle-image accelerometry: Methods and accuracy

Show full item record

Bookmark or cite this item: http://hdl.handle.net/2142/267

Files in this item

File Description Format
PDF 991.pdf (5MB) (no description provided) PDF
Title: Measurement of instantaneous Eulerian acceleration fields by particle-image accelerometry: Methods and accuracy
Author(s): Christensen, Kenneth T.; Adrian, Ronald J.
Subject(s): boundary layers convection environmental effects experimental fluid mechanics geophysical fluid dynamics microfluidics multiphase flows particulate flows turbulence physics
Abstract: Acceleration is a fundamental quantity in fluid mechanics because it reflects the sum of all forces (pressure and viscous) present within the flow. However, measurements of acceleration have been difficult to achieve relative to the ease with which fluid velocity can be measured. A particle-image accelerometer (PIA) has been developed to measure Eulerian acceleration fields by time-differencing successive measurements of the Eulerian velocity field as measured by particle-image velocimetry (PIV). The measurements can also be made in uniformly translating frames. With current video camera technology, it is often not possible to measure the two velocity fields with a time separation sufficiently small enough to permit accurate finite difference approximation of the time derivative. A two-CCD-camera system has been developed to alleviate this limitation. Polarization filtering is utilized to separate the particle images viewed by each camera. The polarization filtering is achieved using cross-polarized light-sheets and a polarization filter just upstream of the imaging optics of the cameras. In this manner, PIV measurements can be achieved easily at time delays several orders of magnitude smaller than the shutter-time of the CCD cameras. The accuracy of the acceleration measurements is determined by numerical finite differencing errors and random noise and bias errors associated with the measurement of velocity. These errors, and methods of compensating for them, are studied.
Issue Date: 2001-12
Publisher: Department of Theoretical and Applied Mechanics (UIUC)
Series/Report: TAM Reports 991
Genre: Technical ReportArticle
Type: Text
Language: English
URI: http://hdl.handle.net/2142/267
ISSN: 0073-5264
Publication Status: published or submitted for publication
Peer Reviewed: is peer reviewed
Is Version Of: Published as: Kenneth T. Christensen and Ronald J. Adrian. Measurement of instantaneous Eulerian acceleration fields by particle-image accelerometry: Methods and accuracy. Experiments in Fluids, Vol. 33, No. 6, 2002, pp. 759-769. DOI: 10.1007/s00348-002-0488-6. Copyright 2002 Springer Verlag.
 

This item appears in the following Collection(s)

  • Theoretical and Applied Mechanics (TAM) Technical Reports
    TAM technical reports include manuscripts intended for publication, theses judged to have general interest, notes prepared for short courses, symposia compiled from outstanding undergraduate projects, and reports prepared for research-sponsoring agencies.

Show full item record

Item Statistics

  • Total Downloads: 298
  • Downloads this Month: 4
  • Downloads Today: 0

Browse

My Account

Information

Access Key