Browse Air Conditioning and Refrigeration Center (ACRC) by Title

  • Winkler, C.M.; Vanka, S.P.; Hrnjak, P.S. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 2002-10)
    In the current dissertation work, the preferential concentration and deposition of heavy solid particles in a downward, fully developed turbulent square duct flow are studied using large eddy simulations. A second-order ...

    application/pdf

    application/pdfPDF (5Mb)
  • Tafti, D.K.; Zhang, X.; Huang, W.; Wang, G. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 2000-04)
    The paper describes the computational procedure and results from large-eddy simulations in a complex three-dimensional louver geometry. The three-dimensionality in the louver geometry occurs along the height of the fin, ...

    application/pdf

    application/pdfPDF (2Mb)
  • Krueger, B.A.; Krueger, B.D.; Newell, T.A.; Chato, J.C. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 2000-12)
    A number of new alternative refrigerants have been proposed in the past several years to replace the existing refrigerants used in air-conditioning equipment. In order to study these refrigerants extensively an in-depth ...

    application/pdf

    application/pdfPDF (2Mb)
  • Kearney, S.P.; Jacobi, A.M. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1995-01)
    Finned tube heat exchangers are important because of their direct impact on energy and material use in petrochemical, power, transportation, and HV AC/R systems. The design of effective heat exchangers has direct social, ...

    application/pdf

    application/pdfPDF (4Mb)
  • Georgiadis, J.G.; Ramaswamy, M. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1995-10)
    Full-field quantitative visualization of freezing interfaces requires the introduction of high resolution noninvasive methods. Magnetic Resonance Imaging (MRI) is a versatile tool for mapping the distribution of liquids ...

    application/pdf

    application/pdfPDF (2Mb)
  • Drozdek, J.C.; Chappell, J.D.; Cusano, C.; Hrnjak, P.S.; Miller, N.R.; Newell, T.A. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 2000-07)
    A study was performed on a swashplate compressor to determine the state of lubrication. Measurements of electrical resistance were taken as a primary measure of oil film lubrication at the sliding shoe/swashplate interface. ...

    application/pdf

    application/pdfPDF (4Mb)
  • Chappell, J.D.; Drozdek, J.C.; Cusano, C.; Hrnjak, P.S.; Miller, N.R.; Newell, T.A. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 2000-07)
    This study used previously developed instrumentation to determine the state of compressor lubrication in an automotive NC system during three transient tests. The primary technique used in the study was measurement of ...

    application/pdf

    application/pdfPDF (6Mb)
  • Rybnikar, F.; Geil, P.H. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1992-05)
    The morphology of a number of polyamides (P A) of current and potential use for mobile air conditioning and refrigerant tubing, namely PA-6, PA-66, PA-6/PA-66 blends and PA-6/PA-66 copolymers, as prepared from the melt ...

    application/pdf

    application/pdfPDF (8Mb)
  • Sulfridge, M.A.; Miller, N.R. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 2001-01)
    A new design for a meso-scale (miniature) compressor has been developed and analyzed. The tenn meso is used to describe a device which is smaller than a traditional (i.e. macro) device, and yet larger than the micro ...

    application/pdf

    application/pdfPDF (4Mb)
  • Drozdek, J.C.; Chappell, J.D.; Cusano, C.; Hrnjak, P.S.; Miller, N.R.; Newell, T.A. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 2000-02)
    Understanding lubrication failures at the shoe/swash plate contact of automotive swash plate compressors will greatly enhance the reliability of the air conditioning system. Maintaining proper lubrication is not always ...

    application/pdf

    application/pdfPDF (724Kb)
  • Barnes, P.R.; Bullard, C.W. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 2000-08)
    A simulation model was developed to investigate strategies for reducing total equivalent warming impact (TEWI) in compact water chillers. The focus was on minimizing R-410A refrigerant charge while increasing efficiency. ...

    application/pdf

    application/pdfPDF (3Mb)
  • Zietlow, D.C.; VanderZee, J.C.; Pederson, C.O. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1993-09)
    This study uses a semi-theoretical steady state computer simulation of an automotive air conditioning system to evaluate design options. The simulation has been validated with experimental data. Influence coefficients ...

    application/pdf

    application/pdfPDF (2Mb)
  • Fang, X. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1999-06)
    The transcritical cycle of carbon dioxide in air conditioning and heat pump systems needs the research on heat transfer and pressure loss of heat exchangers operating at supercritical pressures. This paper offers a ...

    application/pdf

    application/pdfPDF (2Mb)
  • Wood, A.C. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1996-09)
    Due to recent regulations concerning several fluids used in conventional supermarket refrigeration systems, the supermarket industry is investigating the use of secondary refrigeration systems. Because secondary systems ...

    application/pdf

    application/pdfPDF (12Mb)
  • Reeves, R.N. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1992-01)
    This paper examines a set of simple equations describing a domestic refrigerator/freezer system and suggests several modeling improvements, based on experimental results. The experimental setup is described and limitations ...

    application/pdf

    application/pdfPDF (4Mb)
  • Porter, K.J.; Bullard, C.W. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1992-12)

    application/pdf

    application/pdfPDF (4Mb)
  • El Sherbini, A.I.; Jacobi, A.M. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 2003-02)
    Water usually condenses on the air-side surfaces of evaporators in air-conditioning and refrigeration applications. The accumulating condensate on a heat exchanger significantly affects its thermal and hydraulic performance. ...

    application/pdf

    application/pdfPDF (4Mb)
  • Darr, J.H. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1992-02)
    The objective of the current study was to develop a model for the steady-state performance of a reciprocating automotive air conditioning compressor. The model equations were composed of analytical equations based on ...

    application/pdf

    application/pdfPDF (3Mb)
  • Hurlburt, E.T. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1997-08)
    Zeotropic refrigerant mixtures are of interest to the air-conditioning and refrigeration industry. In experiments on evaporators and condensers using zeotropic mixtures, heat transfer has been observed to be less than ...

    application/pdf

    application/pdfPDF (12Mb)
  • Vij, A.K.; Dunn, W.E. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1996-05)
    This work focusses on the modeling of two-phase flows in horizontal, constant-crosssection tubes by a two-fluid approach. The objectives are to develope a framework for two-fluid modeling, to highlight issues related to ...

    application/pdf

    application/pdfPDF (7Mb)