Browse Technical Reports - Air Conditioning and Refrigeration Center by Author "Mullen, C.E."

  • Mullen, C.E.; Bridges, B.D.; Porter, K.J.; Hahn, G.W.; Bullard, C.W. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1997-04)
    Component submodels for a room air conditioner computer simulation were developed and validated using data from a 1.5-ton room air conditioner. The room air conditioner was tested over an extremely wide range: both indoor ...

    application/pdf

    application/pdfPDF (2Mb)
  • Mullen, C.E.; Bullard, C.W. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1994-07)
    Increasingly stringent energy standards and the redesigning of room air conditioners for use with alternative refrigerants have highlighted the need for design and simulation models that are accurate, easy to modify, and ...

    application/pdf

    application/pdfPDF (533Kb)