Browse Technical Reports - Air Conditioning and Refrigeration Center by Author "Zeitlow, D.C."

  • Zeitlow, D.C.; Pederson, C.O. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1995-04)
    This study is the first to model and experimentally validate refrigerant inventory of R134a in small-channel cross-flow condenserst. This heat exchanger is used in automotive applications and uses smaller internal volumes ...

    application/pdf

    application/pdfPDF (7Mb)
  • Zeitlow, D.C.; Ragazzi, F.; Pederson, C.O. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1992-04)
    A steady-state computer simulation based on fundamental principles was developed to model air-cooled condensers. It consists of dividing the total condenser length into a few segments which are further divided into several ...

    application/pdf

    application/pdfPDF (817Kb)
  • Orth, L.A.; Zeitlow, D.C.; Pederson, C.O. (Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign., 1993-04)
    Currently, the refrigerant inventory for vapor compression systems is determined using a costly trial and error procedure. An accurate computer model of the refrigerant in a system would reduce the time and expense ...

    application/pdf

    application/pdfPDF (3Mb)