Title: Steady-State Performance of a Domestic Refrigerator/Freezer Using R12 and R134a
Author(s): Staley, D.M.; Bullard, C.W.; Crawford, R.R.
Subject(s): analysis of refrigerator-freezer systems
Abstract: This paper develops a steady-state system design model for a standard 18 ft3 refrigerator/freezer. Models for the compressor, condenser, evaporator, and suction line interchanger are considered. Experimental data for both R12 and R134a are used as a basis to calibrate the models and as a basis of comparison of model validity for different refrigerants. For each model, a set of independent model parameters are determined from the experimental data using optimization methods. For the heat exchangers both constant conductance and variable conductance models are considered. Lastly, a preliminary overview is made of the applicability of a quasi-steady refrigerator model for use in describing normal cycling operation of a refrigerator/freezer.
Issue Date: 1992-06
Publisher: Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign.
Series/Report: Air Conditioning and Refrigeration Center TR-22
Genre: Technical Report
Type: Text
Language: English
URI: http://hdl.handle.net/2142/9723
Sponsor: Air Conditioning and Refrigeration Center Project 12