<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="/oai-pmh.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-09-21T09:57:33Z</responseDate>
  <request identifier="oai:www.ideals.illinois.edu:2142/25860" metadataPrefix="etdms" verb="GetRecord">https://www.ideals.illinois.edu/oai-pmh</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:www.ideals.illinois.edu:2142/25860</identifier>
        <datestamp>2023-07-10</datestamp>
        <setSpec>col_2142_8859</setSpec>
        <setSpec>col_2142_5131</setSpec>
        <setSpec>com_2142_8858</setSpec>
        <setSpec>com_2142_234</setSpec>
        <setSpec>com_2142_5130</setSpec>
      </header>
      <metadata>
        <thesis xmlns="http://www.ndltd.org/standards/metadata/etdms/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.ndltd.org/standards/metadata/etdms/1.1/ http://www.ndltd.org/standards/metadata/etdms/1.1/etdms11.xsd http://purl.org/dc/elements/1.1/ http://www.ndltd.org/standards/metadata/etdms/1.1/etdmsdc.xsd">
          <dc:contributor>Simmons, R.O.</dc:contributor>
          <dc:creator>Windecker, Richard Chase</dc:creator>
          <dc:date>2011-07-27T15:58:22Z</dc:date>
          <dc:date>2011-07-27T15:58:22Z</dc:date>
          <dc:date>10000-01-01</dc:date>
          <dc:date>1970</dc:date>
          <dc:description>"Measurements of integrated intensities of X-ray Bragg reflections have been
made as a function of temperature on two large single crystal specimens of solid
krypton. These data have been interpreted in terms of a Debye characteristic
temperature, 8
M
"" according to the method suggested by Nicklow and Young. The
specimens were prepared and maintained in a specially designed and constructed
rigid-tail liquid helium cryostat and the measurements were made with a fourcircle
X-ray diffractometer designed for use with this cryostat.
The values of 8M, obtained in this work show a general qualitative agreement
with existing quasi-harmonic and anharmonic theories, but suggest that
further refinement is needed in the anharmonic theories. These results are also
in general agreement with other thermodynamic data on solid krypton obtained by
a diversity of experiments, including heat capacity measurements, vapor pressure
measurements, entropy measurements, and neutron phonon dispersion measurements.
On the other hand, the results of the present experiment disagree sharply with
two previous experiments based on the Mossbauereffect, implying that there was
some difficulty inherent in the Mossbauer methods.
The high and low temperature expansions of 8M, in the harmonic approximation
have been obtained showing that the high- and low-temperature limiting values of
8M, in this approximation are 8(-2) and 8(-3), respectively. The experimental
value of 8(-2) obtained by this work is 67 +.5 K."</dc:description>
          <dc:description>Submitted by Carolyn Mead (cmead2@illinois.edu) on 2011-07-27T15:58:22Z
No. of bitstreams: 1
1970_windecker.pdf: 4251240 bytes, checksum: 9d09f4d384ed40c23c5109765eddb383 (MD5)</dc:description>
          <dc:description>Made available in DSpace on 2011-07-27T15:58:22Z (GMT). No. of bitstreams: 1
1970_windecker.pdf: 4251240 bytes, checksum: 9d09f4d384ed40c23c5109765eddb383 (MD5)
  Previous issue date: 1970</dc:description>
          <dc:description>Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Carolyn Mead (cmead2@illinois.edu) on 2011-07-27T15:58:22Z
Item is restricted indefinitely.</dc:description>
          <dc:description>Restriction data tranferred 2014-07-01T11:33:11-05:00
Original Data
Group with Access UIUC Users [automated]
Release Date: none
Reason: Thesis</dc:description>
          <dc:description>Thesis</dc:description>
          <dc:description>U of I Only</dc:description>
          <dc:identifier>6031827</dc:identifier>
          <dc:identifier>http://hdl.handle.net/2142/25860</dc:identifier>
          <dc:language>en</dc:language>
          <dc:rights>1970 Richard Chase Windecker</dc:rights>
          <dc:subject>x-ray debye temperature</dc:subject>
          <dc:subject>solid krypton</dc:subject>
          <dc:subject>x-ray Bragg reflections</dc:subject>
          <dc:title>The X-ray Debye temperature of solid krypton</dc:title>
          <dc:type>Dissertation / Thesis</dc:type>
          <dc:type>text</dc:type>
          <degree>
            <department>Physics</department>
            <discipline>Physics</discipline>
            <disciplineCode>University of Illinois at Urbana-Champaign</disciplineCode>
            <level>Dissertation</level>
            <name>Ph.D.</name>
          </degree>
        </thesis>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
