<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="/oai-pmh.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-09-21T02:49:21Z</responseDate>
  <request identifier="oai:www.ideals.illinois.edu:2142/30886" metadataPrefix="etdms" verb="GetRecord">https://www.ideals.illinois.edu/oai-pmh</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:www.ideals.illinois.edu:2142/30886</identifier>
        <datestamp>2023-07-10</datestamp>
        <setSpec>col_2142_5131</setSpec>
        <setSpec>col_2142_14770</setSpec>
        <setSpec>com_2142_5130</setSpec>
        <setSpec>com_2142_3518</setSpec>
        <setSpec>com_2142_234</setSpec>
      </header>
      <metadata>
        <thesis xmlns="http://www.ndltd.org/standards/metadata/etdms/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.ndltd.org/standards/metadata/etdms/1.1/ http://www.ndltd.org/standards/metadata/etdms/1.1/etdms11.xsd http://purl.org/dc/elements/1.1/ http://www.ndltd.org/standards/metadata/etdms/1.1/etdmsdc.xsd">
          <dc:contributor>Rood, Mark J.</dc:contributor>
          <dc:contributor>Rostam-Abadi, Massoud</dc:contributor>
          <dc:contributor>Rood, Mark J.</dc:contributor>
          <dc:creator>Sugiyono, Ivan</dc:creator>
          <dc:date>2012-05-22T00:13:17Z</dc:date>
          <dc:date>2012-05-22T00:13:17Z</dc:date>
          <dc:date>2012-05</dc:date>
          <dc:date>2012-05-22T00:13:17Z</dc:date>
          <dc:date>2012-05</dc:date>
          <dc:description>Coal-fired power plants produce 40 % of the total electricity in the United States. The
flue gas generated from burning coal contains air pollutants including sulfur oxides (SOx),
hydrochloric acid (HCl) and elemental and ionic mercury (Hgo and Hg2+). A process option to
remove these pollutants from the flue gas is by injection of sorbents downstream of a boiler and
up-stream of a particulate control device. Activated carbon (AC) is a suitable sorbent to capture
vapor-phase mercury and calcium-based sorbents such as quicklime (CaO) and hydrated lime
(Ca(OH)2) are suitable sorbents to capture SOx and HCl. This research addresses producing
quicklime by a novel process to remove SOx and HCl from flue gas streams. Quicklime is
commercially prepared by thermal decomposition of limestone (CaCO3) in a rotary kiln. The
surface area of commercial quicklime, a key parameter of reactivity, is typically &lt; 2 m2/g.
Therefore, increasing the surface area of quicklime in a cost-effective process would enhance its
effectiveness as a sorbent for control of combustion-generated air pollutants.
Illinois State Geological Survey (ISGS), a division of the Prairie Research Institute at the
University of Illinois at Urbana Champaign (UIUC), and Electric Power Research Institute
(EPRI), Palo Alto, CA, have developed a patent-pending Sorbent Activation Process (SAP)
technology for on-site production and direct injection of quicklime into flue gas generated by
coal fired power plants (US Patent Application 20,110,223,088). This process is an extension of
a similar patented process for on-site production of activated carbon (AC) to remove vapor-phase
mercury emissions in the flue gas (US Patents 6, 451, 094 and 6,558,454). SAP utilizes an
entrained-flow reactor in which sorbent (AC or quicklime) particles are subjected to a &lt; 5 second
residence time during their production. On-site production of quicklime could help lower the
production cost of quicklime sorbent for dry sorbent injection (DSI) applications.
In this research, a bench-scale SAP unit (2 kg/hr limestone feed rate) was used to prepare
quicklime from two limestone samples. The impacts of particle size, surface morphologies of
limestone, and operating parameters of SAP including temperature profile, and residence time on
the product quicklime were investigated. SAP experiments were designed to provide engineering
data and guidelines for operating a pilot-scale (20 kg/hr limestone feed rate) and designing a fullscale
SAP units (135 kg/hr limestone feed rate) currently being tested at a coal-fired power plant
in the United States. Additionally, kinetic information about calcination of the two limestone samples was obtained from the analysis of non-isothermal decomposition measured by
thermogravimetric analysis (TGA) method. Furthermore, the kinetic information was used to
predict limestone calcination in SAP.
Lime sorbents prepared in SAP contained between 20 and 80 wt % calcium oxide
(balance calcium carbonate) and had surface areas ranging between 5 and 12 m2/g depending on
operation conditions employed. Non-isothermal TGA experiments were analyzed by several data
analysis approaches including Coats-Redfern, Criado linearization and DTG-curve fitting
method using DTG-SIM software to obtain the kinetic parameters (activation energy, frequency
factor, and reaction order) for thermal decomposition (calcination) of the two limestone samples.
The values of the kinetic parameters were in good agreement with those previously reported in
the literature. The kinetic models predicted the experimental TGA calcination in N2 with less
than 10% deviation. However, only the Coats-Redfern-based kinetic model predicted the TGA
calcinations in CO2 data with less than 10 % deviation. The kinetic parameters were used to
predict limestone conversions in an ideal flash calciner and in SAP. Ideal flash calciner assumed
isothermal condition throughout the reactor while the later one used the actual temperature
profiles in SAP to predict limestone conversion at different CO2 partial pressures. The impact of
mass and heat transfer limitation, lime sintering phenomenon, and particle size distribution of
limestone/lime were not included in the model. The experimental limestone conversions were
higher than those predicted by the models.
Based on the results from SAP experiments and model predictions, it was concluded that
the actual temperature of limestone particle was likely much higher than the gas temperature
measured in SAP. Future work should include: 1) installation of additional thermocouples to
continuously monitor both axial and radial temperature profiles in the SAP, 2) an understanding
of the flow pattern and hydrodynamic inside the SAP to better estimate gas-gas and gas-solid
mixing, 3) testing several size-graded limestone samples to evaluate the impact of particle size
on limestone calcination, 4) calibrating the propane and combustion air flow rates to obtain more
accurate readings, 5) quantify the extent of particle deposition in SAP, 6) measure gas phase
concentrations of CO, CO2, O2, NOx, and hydrocarbons (HCs), and verify those measured
values, and 7) incorporate mass and heat transports effects in the model to better predict
calcination performance of limestone in bench-, pilot-, and full-scale SAPs.</dc:description>
          <dc:description>Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2012-04-26T15:10:46Z
Item was in collections:
University of Illinois Theses &amp; Dissertations (ID: 1)
No. of bitstreams: 2
Sugiyono_Ivan.docx: 26270075 bytes, checksum: 90280568f10ae5aa97e64630f518decd (MD5)
Sugiyono_Ivan.pdf: 5904153 bytes, checksum: 3426dd7e6000c794268bfa0fdde3bc73 (MD5)</dc:description>
          <dc:description>Made available in DSpace on 2012-05-22T00:13:17Z (GMT). No. of bitstreams: 3
SUGIYONO_IVAN.pdf: 6631521 bytes, checksum: 2dad005be7bbfd3e6daaac603c492b86 (MD5)
Sugiyono_Ivan.docx: 26252664 bytes, checksum: 1df482b57c91d45c433432eacec2f2d2 (MD5)
license.txt: 4063 bytes, checksum: d71b6b9c8faef752fc5811fb48d845e8 (MD5)</dc:description>
          <dc:identifier>http://hdl.handle.net/2142/30886</dc:identifier>
          <dc:language>en</dc:language>
          <dc:rights>Copyright 2012 Ivan Sugiyono</dc:rights>
          <dc:subject>Sorbent Activation Process</dc:subject>
          <dc:subject>flue gas desulfurization</dc:subject>
          <dc:subject>mercury capture</dc:subject>
          <dc:subject>flash calcination</dc:subject>
          <dc:subject>high surface area</dc:subject>
          <dc:subject>calcium-based sorbent</dc:subject>
          <dc:title>Flash calcination of limestone in a bench-scale sorbent activation process (SAP) unit</dc:title>
          <dc:type>text</dc:type>
          <degree>
            <department>Civil &amp; Environmental Eng</department>
            <departmentCode>1251</departmentCode>
            <discipline>Environ Engr in Civil Engr</discipline>
            <disciplineCode>0231</disciplineCode>
            <grantor>University of Illinois at Urbana-Champaign</grantor>
            <level>Thesis</level>
            <name>M.S.</name>
            <program>MS:Env Engr  Civil Engr -UIUC</program>
            <programCode>10KS0231MS</programCode>
          </degree>
        </thesis>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
