<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="/oai-pmh.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-09-22T17:07:11Z</responseDate>
  <request identifier="oai:www.ideals.illinois.edu:2142/81022" metadataPrefix="etdms" verb="GetRecord">https://www.ideals.illinois.edu/oai-pmh</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:www.ideals.illinois.edu:2142/81022</identifier>
        <datestamp>2023-07-11</datestamp>
        <setSpec>col_2142_5131</setSpec>
        <setSpec>col_2142_8888</setSpec>
        <setSpec>com_2142_5130</setSpec>
        <setSpec>com_2142_8887</setSpec>
        <setSpec>com_2142_234</setSpec>
      </header>
      <metadata>
        <thesis xmlns="http://www.ndltd.org/standards/metadata/etdms/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.ndltd.org/standards/metadata/etdms/1.1/ http://www.ndltd.org/standards/metadata/etdms/1.1/etdms11.xsd http://purl.org/dc/elements/1.1/ http://www.ndltd.org/standards/metadata/etdms/1.1/etdmsdc.xsd">
          <dc:contributor>Stephen Allen Boppart</dc:contributor>
          <dc:creator>Zysk, Adam Michael</dc:creator>
          <dc:date>2015-09-25T20:09:15Z</dc:date>
          <dc:date>2015-09-25T20:09:15Z</dc:date>
          <dc:date>10000-01-01</dc:date>
          <dc:date>2007</dc:date>
          <dc:date>2007</dc:date>
          <dc:description>These findings have been applied to the clinical problems of metastatic cell identification and biopsy needle localization. The latter is important due to the high rate of nondiagnostic tissue removal using current guidance techniques. Up to 10% of the approximately one million breast needle biopsies performed every year in the United States yield incorrect samples and inconclusive diagnoses, often resulting in additional surgical procedures. This poor outcome is due in large part to the inability of clinicians to spatially localize suspicious tissues during biopsy procedures. This problem has been addressed with the development of a clinically compatible fiber optic needle device capable of accurately measuring refractive index and scattering in situ. Preliminary intraoperative investigations with this device have yielded promising results.</dc:description>
          <dc:description>Made available in DSpace on 2015-09-25T20:09:15Z (GMT). No. of bitstreams: 2
license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5)
3270070.pdf: 5302164 bytes, checksum: 5b9e781cf45eb1a103da91102f281a90 (MD5)
  Previous issue date: 2007</dc:description>
          <dc:description>Embargo set by: Seth Robbins for item 82304
Lift date: Forever
Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs</dc:description>
          <dc:description>Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs</dc:description>
          <dc:description>U of I Only</dc:description>
          <dc:description>131 p.</dc:description>
          <dc:description>Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2007.</dc:description>
          <dc:identifier>http://hdl.handle.net/2142/81022</dc:identifier>
          <dc:identifier>(MiAaPQ)AAI3270070</dc:identifier>
          <dc:language>eng</dc:language>
          <dc:subject>Engineering, Biomedical</dc:subject>
          <dc:title>Surgical Breast Cancer Localization via Coherent Measurement of Endogenous Optical Properties</dc:title>
          <dc:type>text</dc:type>
          <degree>
            <department>Electrical and Computer Engineering</department>
            <discipline>Electrical and Computer Engineering</discipline>
            <grantor>University of Illinois at Urbana-Champaign</grantor>
            <level>Dissertation</level>
            <name>Ph.D.</name>
          </degree>
        </thesis>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
