<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="/oai-pmh.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-09-20T18:07:11Z</responseDate>
  <request identifier="oai:www.ideals.illinois.edu:2142/81128" metadataPrefix="etdms" verb="GetRecord">https://www.ideals.illinois.edu/oai-pmh</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:www.ideals.illinois.edu:2142/81128</identifier>
        <datestamp>2023-07-11</datestamp>
        <setSpec>col_2142_5131</setSpec>
        <setSpec>col_2142_8888</setSpec>
        <setSpec>com_2142_5130</setSpec>
        <setSpec>com_2142_8887</setSpec>
        <setSpec>com_2142_234</setSpec>
      </header>
      <metadata>
        <thesis xmlns="http://www.ndltd.org/standards/metadata/etdms/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.ndltd.org/standards/metadata/etdms/1.1/ http://www.ndltd.org/standards/metadata/etdms/1.1/etdms11.xsd http://purl.org/dc/elements/1.1/ http://www.ndltd.org/standards/metadata/etdms/1.1/etdmsdc.xsd">
          <dc:contributor>Cunningham, Brian T.</dc:contributor>
          <dc:creator>Lu, Meng</dc:creator>
          <dc:date>2015-09-25T20:09:41Z</dc:date>
          <dc:date>2015-09-25T20:09:41Z</dc:date>
          <dc:date>10000-01-01</dc:date>
          <dc:date>2009</dc:date>
          <dc:date>2009</dc:date>
          <dc:description>The DFB laser sensor represents a departure from conventional passive resonant sensors insofar as the device actively generates its own narrowband high-intensity output without stringent requirements on the coupling alignments resulting in a simple, robust illumination and detection configuration. The DFB laser sensor structures that are fabricated upon plastic substrate in an inexpensive replica molding process render this sensor of value for applications in life science research, diagnostic testing, and environmental monitoring.</dc:description>
          <dc:description>Made available in DSpace on 2015-09-25T20:09:41Z (GMT). No. of bitstreams: 2
license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5)
3363026.pdf: 1439977 bytes, checksum: 64208034cac0718203fb37a401fcc49f (MD5)
  Previous issue date: 2009</dc:description>
          <dc:description>Embargo set by: Seth Robbins for item 82410
Lift date: Forever
Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs</dc:description>
          <dc:description>Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs</dc:description>
          <dc:description>U of I Only</dc:description>
          <dc:description>100 p.</dc:description>
          <dc:description>Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2009.</dc:description>
          <dc:identifier>http://hdl.handle.net/2142/81128</dc:identifier>
          <dc:identifier>(MiAaPQ)AAI3363026</dc:identifier>
          <dc:language>eng</dc:language>
          <dc:subject>Engineering, Biomedical</dc:subject>
          <dc:title>Label-Free Biosensor Based Upon Replica-Molded Vertically Emitting Distributed Feedback Laser</dc:title>
          <dc:type>text</dc:type>
          <degree>
            <department>Electrical and Computer Engineering</department>
            <discipline>Electrical and Computer Engineering</discipline>
            <grantor>University of Illinois at Urbana-Champaign</grantor>
            <level>Dissertation</level>
            <name>Ph.D.</name>
          </degree>
        </thesis>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
