<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="/oai-pmh.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-09-22T10:12:11Z</responseDate>
  <request identifier="oai:www.ideals.illinois.edu:2142/83931" metadataPrefix="etdms" verb="GetRecord">https://www.ideals.illinois.edu/oai-pmh</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:www.ideals.illinois.edu:2142/83931</identifier>
        <datestamp>2023-07-11</datestamp>
        <setSpec>col_2142_5131</setSpec>
        <setSpec>col_2142_14787</setSpec>
        <setSpec>com_2142_5130</setSpec>
        <setSpec>com_2142_9630</setSpec>
        <setSpec>com_2142_234</setSpec>
      </header>
      <metadata>
        <thesis xmlns="http://www.ndltd.org/standards/metadata/etdms/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.ndltd.org/standards/metadata/etdms/1.1/ http://www.ndltd.org/standards/metadata/etdms/1.1/etdms11.xsd http://purl.org/dc/elements/1.1/ http://www.ndltd.org/standards/metadata/etdms/1.1/etdmsdc.xsd">
          <dc:contributor>Chia-Fon F. Lee</dc:contributor>
          <dc:creator>Powell, Joshua W.</dc:creator>
          <dc:date>2015-09-25T21:12:46Z</dc:date>
          <dc:date>2015-09-25T21:12:46Z</dc:date>
          <dc:date>10000-01-01</dc:date>
          <dc:date>2009</dc:date>
          <dc:date>2009</dc:date>
          <dc:description>No discernible difference was seen between exciplex and pentanone tracers in atmospheric conditions and both gave good agreement with the PDA data. The PDA typically reported a wider spray because had to record for a much longer time to pick up enough droplets, increasing the chances of picking up outlying droplets that would not be seen in the much faster PDS imaging. PDS generally showed slightly larger SMD where the spray cone was. This was because PDS was not biased towards the more statistically likely smaller droplets. (Abstract shortened by UMI.).</dc:description>
          <dc:description>Made available in DSpace on 2015-09-25T21:12:46Z (GMT). No. of bitstreams: 2
license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5)
3363057.pdf: 14229584 bytes, checksum: 7cbce60546512dcdd2a63a4bf728def3 (MD5)
  Previous issue date: 2009</dc:description>
          <dc:description>Embargo set by: Seth Robbins for item 85212
Lift date: Forever
Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs</dc:description>
          <dc:description>Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs</dc:description>
          <dc:description>U of I Only</dc:description>
          <dc:description>274 p.</dc:description>
          <dc:description>Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2009.</dc:description>
          <dc:identifier>http://hdl.handle.net/2142/83931</dc:identifier>
          <dc:identifier>(MiAaPQ)AAI3363057</dc:identifier>
          <dc:language>eng</dc:language>
          <dc:subject>Engineering, Mechanical</dc:subject>
          <dc:title>A Quantitative Assessment of Droplet Sizes in Atmospheric and Engine Environments</dc:title>
          <dc:type>text</dc:type>
          <degree>
            <department>Mechanical Engineering</department>
            <discipline>Mechanical Engineering</discipline>
            <grantor>University of Illinois at Urbana-Champaign</grantor>
            <level>Dissertation</level>
            <name>Ph.D.</name>
          </degree>
        </thesis>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
