Withdraw
Loading…
Distributed Feedback Laser Biosensor in Microplate Format
Tan, Yafang
Content Files

Loading…
Download Files
Loading…
Download Counts (All Files)
Loading…
Edit File
Loading…
Permalink
https://hdl.handle.net/2142/29649
Description
- Title
- Distributed Feedback Laser Biosensor in Microplate Format
- Author(s)
- Tan, Yafang
- Issue Date
- 2012-02-06T20:08:44Z
- Director of Research (if dissertation) or Advisor (if thesis)
- Cunningham, Brian T.
- Department of Study
- Electrical & Computer Eng
- Discipline
- Electrical & Computer Engr
- Degree Granting Institution
- University of Illinois at Urbana-Champaign
- Degree Name
- M.S.
- Degree Level
- Thesis
- Date of Ingest
- 2012-02-06T20:08:44Z
- Keyword(s)
- nanoreplica molding
- horizontal dipping
- distributed feedback laser biosensors (DFBLB)
- tumor necrosis factor-alpha (TNF-α)
- Abstract
- A process that combines polymer anoreplica molding with horizontal dipping was used to fabricate large area (~3x5 in2) distributed feedback laser biosensors (DFBLB) on flexible plastic substrates, which were subsequently incorporated into standard format 96-well microplates. A room temperature nanoreplica molding process was used to create subwavelength periodic grating structures, while a horizontal dipping process was used to apply a ~300 nm, dye-doped polymer film. In this work, the DFBLB emission wavelength, used to characterize the device uniformity, demonstrated a coefficient of variation (CV) of 0.41% over the fabricated device area, representing a thickness standard deviation of only ~35 nm for the horizontal dipping process.The fabricated sensors were further characterized for sensitivity uniformity by measuring the bulk refractive index of the media exposed to the sensor surface and by measuring adsorption of biomolecular layers. An assay for detection of the cytokine tumor necrosis factor-alpha (TNF-α) was used to demonstrate the operation of the sensor in the context of label-free detection of a disease biomarker. The demonstrated capability represents an important step towards roll-to-roll manufacturability for this biosensor that simultaneously incorporates high sensitivity with excellent wavelength shift resolution, and adaptability to the microplate format that is ubiquitous in pharmaceutical research.
- Graduation Semester
- 2011-12
- Permalink
- http://hdl.handle.net/2142/29649
- Copyright and License Information
- Copyright 2011 Yafang Tan
Owning Collections
Graduate Dissertations and Theses at Illinois PRIMARY
Graduate Theses and Dissertations at IllinoisDissertations and Theses - Electrical and Computer Engineering
Dissertations and Theses in Electrical and Computer EngineeringManage Files
Loading…
Edit Collection Membership
Loading…
Edit Metadata
Loading…
Edit Properties
Loading…
Embargoes
Loading…