Withdraw
Loading…
"""Green-Friendly"" Best Management Practices (BMPs) for Interstate Rest Areas—Phase II"
El-Rayes, Khaled; Liu, Liang; Abdallah, Moatassem
Loading…
Permalink
https://hdl.handle.net/2142/45752
Description
- Title
- """Green-Friendly"" Best Management Practices (BMPs) for Interstate Rest Areas—Phase II"
- Author(s)
- El-Rayes, Khaled
- Liu, Liang
- Abdallah, Moatassem
- Issue Date
- 2013-06
- Keyword(s)
- Performance of green building measures
- green-friendly best management practices
- decision support tool
- LEED certification
- sub-metering systems.
- Abstract
- Interstate rest area buildings in Illinois range in age from 10 to nearly 50 years old and are on display and used 365 days a year by nearly 40 million people annually. The rest area sites comprise 53 buildings that provide restroom facilities, vending machines, and 11 welcome centers. These facilities are presently being maintained within the allowable budgets; however, they are in need of upgrades to improve their environmental and economic performance in supporting recent sustainability initiatives in Illinois. The main goal of this project was to investigate, determine, and recommend a list of green-friendly best management practices (BMPs) for the six interstate rest areas that have the highest energy consumption in Illinois. These six rest areas are Willow Creek, Coalfield, Great Sauk Trail, Mackinaw Dells, Cumberland Road, and Turtle Creek, which account for 32% of IDOT’s rest area energy bills. The main results and findings of this study include (1) an online survey of state departments of transportation (DOTs) conducted to gather information on their experiences in implementing green-friendly measures in rest areas, welcome centers, office buildings, and related buildings; (2) an investigation of installing temporary or permanent sub-metering systems to measure, monitor, and analyze the actual energy consumption of devices and fixtures in the six rest areas; (3) on-site assessments and field measurements of the six rest areas; (4) an identification of energy and water-saving alternatives that can be implemented in the six rest areas, including: LED and induction lighting; motion sensors for interior lighting, vending machines, and exhaust fans; grid-connected photovoltaic systems; solar water heaters; solar tube lighting; double-pane glass, vestibule entrances; Energy Star–rated HVAC systems; geothermal heat pumps; and watersaving plumbing fixtures; (5) an energy audit analysis for the six selected rest areas, using eQuest energy simulation software to analyze the impact of implementing various energy-saving alternatives; (6) an economic analysis of the identified energysaving alternatives for the selected rest areas in terms of their required upgrade costs, life-cycle cost, and payback periods; and (7) a practical and user-friendly decision support tool that is capable of identifying optimal upgrade measures for public buildings in Illinois to achieve a specified Leadership in Energy and Environmental Design ( LEED) certification with the minimum upgrade costs or achieve the highest LEED points within a given upgrade budget.
- Series/Report Name or Number
- FHWA-ICT-13-005
- ISSN
- 0197-9191
- Type of Resource
- text
- Language
- en
- Permalink
- http://hdl.handle.net/2142/45752
- Sponsor(s)/Grant Number(s)
- Illinois Department of Transportation R27-103
- Copyright and License Information
- No restrictions. This document is available to the public through the National Technical Information Service, Springfield, Virginia 22161
Owning Collections
Manage Files
Loading…
Edit Collection Membership
Loading…
Edit Metadata
Loading…
Edit Properties
Loading…
Embargoes
Loading…